PE30 Electrical Specifications
Installation/Setup
Warranty
Contact Us
Links
Home Page
Mechanical Specifications and Wiring
PE30 Dimensions PE30-NO Wiring Diagram
Housing w/mounting nuts:      33% glass-filled nylon 6/12, black

Encapsulation :      epoxy

Cable:     12" pigtail, #18 SAE type SXL, cross-linked polyethylene insulation

Cable Sheath:     Irradiated PVC

Attention OEMs:     We will quote PE30s with cables and connectors to your specifications on orders of 1,000 pcs. or more
PE30-NC Wiring Diagram
Mechanical Specifications Wiring Diagrams


Electrical Specifications
Input Voltage Operating Current
nominal
Leakage Current
maximum
  Output Current
maximum
Output Drop
maximum
10-30 VDC 16 mA 50 uA   700 mA 1. 5 VDC
Standard Target
steel
Sensitivity
over temp. range
Supply Voltage
Sensitivity

maximum
Hysteresis
maximum
Repetition Accuracy
maximum / 100 X
Switching Frequency
maximum
30mm 2 x 1mm
1. 18" 2 x . 04"
10mm +/- 2mm
. 39" +/- . 08"
+/- . 25mm
+/- . 01"
5% of nominal
sensitivity
. 03mm
. 001"
20 Hz
Insulation
Resistance
Voltage
Resistance

for 1 min.
Short-Circuit
Protection

output to supply
Reverse Supply
Voltage
Irregular Supply
Voltage
Load Dump
across supply terminals
50 Megohms
500 VDC
500 VAC
50/60 HZ
withstand direct short
15mS power-off reset
600 VDC
for 30 min.
500 VDC
for 10 uS
withstand 130 VDC
for 100 mS
Shock
Resistance

5X each
Vibration
Resistance

3 mins. each
Temperature
Range
Relative
Humidity
Immersion
Resistance

H2O, 5 mins.
Chemical
Effects

physical/electrical
degradation
25g, 11mS half sine pulses
x, y & z axes
20g
x, y & z axes
-40o C to +71o C
-40o F to +160o F
0 - 95% fully functional
after air dry
none
as a result of exposure to
lubricants, chemicals and
fuels normally used in the farm and automotive industries


Installation/Setup Procedures
Mechanical Installation Electrical Installation
     Use the nuts supplied with the switch to mount it to a bracket with M30 x 1.5 threads or a through-hole for 30mm.

     Multiple units must be spaced at least 20mm apart laterally, and the sensing face of each unit must extend a minimum of 20mm beyond any metal parts or mounting brackets.

     Your switch's electrical connections must agree with those shown in the corresponding wiring diagram above.
Setup Procedure
      These units have a factory-set sensitivity level - adjustment of the switching point is a function of switch positioning.
 