PC30AE Electrical Specifications
Installation/Setup
Warranty
Contact Us
Links
Home Page
Mechanical Specifications and Wiring
PC30AE Dimensions PC30AE-NO Wiring Diagram
Housing w/mounting nuts:    black, 33% glass-filled nylon 6/12;
8-32 threaded insert, for mounting expanded sensing element

Encapsulation :      epoxy

Power/Output Cable:     2 meters ( 4 wires ), standard

Adjustment:     15-turn potentiometer

Output Indicator:     LED, lit when output is conducting
PC30AE-NC Wiring Diagram
Mechanical Specifications Wiring Diagrams


Electrical Specifications
Input Voltage Minimum Load Operating Current
nominal
Output Current
maximum
Leakage Current
maximum
Output Drop
maximum
115 VAC 5 mA 4 mA 500 mA 1 mA 1. 6 VAC
Range
Adjustment

pF
Sensitivity
nominal
Sensitivity
maximum - w/expanded
sensing element
Temperature
Range
Relative
Humidity
General
Environment
0-5 . 6"
15. 2 mm
1. 5"
38. 1 mm
+50o F to +130o F
+10o C to +55o C
0 - 95% unaffected by normal
factory conditions of
dirt, grease and
vibration


Installation/Setup Procedures
Mechanical Installation Electrical Installation
Use the nuts supplied with the switch to mount it to a bracket with M30 x 1.5 threads or a through-hole for 30mm.

Multiple units must be spaced at least 30mm apart, laterally, and the sensing face of each unit must extend 30mm beyond any mounting bracket.

As a general rule, expanded sensing elements must be spaced a minimum of the sensor diameter away from each other.

Your switch's electrical connections must agree with those shown in the corresponding wiring diagram above.
Setup Procedure
Apply power.

With no target present, turn the adjustment potentiometer CW until an alarm condition exists
( Normally Open - LED is lit;  Normally Closed - LED is off ).

Then, turn the pot CCW until the alarm just resets. This is the point of maximum possible sensitivity;
this is not the recommended operating point, however, as temperature fluctuations may cause false alarms or detection failures.

For the optimum setting, put a target at the desired detection point and ensure that the switch is alarmed. Turn the pot CCW until the unit just resets, noting the number of turns to reset. Return CW half this number of turns.


Note:   A minimum of  ¼  turn CW is recommended to ensure stable operation.
 