PCR25 Electrical Specifications
Installation/Setup
Warranty
Contact Us
Links
Home Page
Mechanical Specifications and Wiring
PCR25 Dimensions PCR25-NO Wiring Diagram
Housing :    molded ABS w/ end cap

Encapsulation :      epoxy

Sensor Cable:     3 meters ( tiaxial ), standard
Power/Output Cable:     2 meters ( 4 wires ), standard

Adjustment:     15-turn potentiometer

Output Indicator:     LED, lit when output is conducting
PCR25-NC Wiring Diagram
Mechanical Specifications Wiring Diagrams


Electrical Specifications
Input Voltage Supply Ripple Operating Current
nominal
  Leakage Current
maximum
Output Current
maximum
10-30 VDC 10% 12 mA   2 uA 100 mA
Range
Adjustment

pF
Sensitivity
nominal
Sensitivity
maximum
w/ 3" diameter
remote sensing
element
Temperature
Range
Relative
Humidity
General
Environment
0-5 . 5"
12. 7 mm
1. 5"
38. 1 mm
+50o F to +130o F
+10o C to +55o C
0 - 95% unaffected by normal
factory conditions of
dirt, grease and
vibration


Installation/Setup Procedures
Mechanical Installation Electrical Installation
Use a 12A272 mounting clamp, or its equivalent, to securely mount the sensor.

The remote sensing element must be constructed and secured in a way that prohibits movement of the element, with respect to ground or the object to be detected.

Note : For new installations, you may require an optional 12A907 Triaxial Bulkhead Connector, to interface with your remote sensing element.

Multiple units must be spaced at least 25mm apart, laterally, and, as a general rule, remote sensing elements must be spaced a minimum of the sensor diameter away from each other.
Your switch's electrical connections must agree with those shown in the corresponding wiring diagram above.
Setup Procedure
Apply power.

With no target present, turn the adjustment potentiometer CW until an alarm condition exists
( Normally Open - LED is lit;  Normally Closed - LED is off ).

Then, turn the pot CCW until the alarm just resets. This is the point of maximum possible sensitivity;
this is not the recommended operating point, however, as temperature fluctuations may cause false alarms or detection failures.

For the optimum setting, put a target at the desired detection point and ensure that the switch is alarmed. Turn the pot CCW until the unit just resets, noting the number of turns to reset. Return CW half this number of turns.


Note:   A minimum of  ¼  turn CW is recommended to ensure stable operation.
 